Most cited papers from Debiotech (Switzerland)
What are the most cited papers from Debiotech (Switzerland)?
The most cited paper from Debiotech (Switzerland) is "Static micromixers based on large-scale industrial mixer geometry" (Arnaud Bertsch, Stephan Heimgartner, Peter Cousseau et al., 2001), with 200 citations. Next come "Inhaled Vasoactive Intestinal Peptide Exerts Immunoregulatory Effects in Sarcoidosis" (164) and "Inhalation of vasoactive intestinal peptide in pulmonary hypertension" (131).
Showing 48 of 48 papers. Every paper is listed.
| # | Paper | ||
|---|---|---|---|
| 1 | Static micromixers based on large-scale industrial mixer geometry Arnaud Bertsch, Stephan Heimgartner, Peter Cousseau et al. · Lab on a Chip | 2001 | 200 |
| 2 | Inhaled Vasoactive Intestinal Peptide Exerts Immunoregulatory Effects in Sarcoidosis Antje Prasse, Gernot Zissel, Niklas Lützen et al. · American Journal of Respiratory and Critical Care Medicine | 4 May 2010 | 164 |
| 3 | Inhalation of vasoactive intestinal peptide in pulmonary hypertension Hanno H. Leuchte, Carlos J. Baezner, R. A. Baumgartner et al. · European Respiratory Journal | 31 Oct 2008 | 131 |
| 4 | A high-performance silicon micropump for disposable drug delivery systems D. Maillefer, Siegfried F. Gamper, B. Frehner et al. | 13 Nov 2002 | 104 |
| 5 | A high-performance silicon micropump for an implantable drug delivery system D. Maillefer, Harald van Lintel, Gilles Rey-Mermet et al. | 1999 | 98 |
| 6 | A Dual Mode Adaptive Basal-Bolus Advisor Based on Reinforcement Learning Qingnan Sun, Marko V. Jankovic, Joao Budzinski et al. · IEEE Journal of Biomedical and Health Informatics | 18 Dec 2018 | 72 |
| 7 | Minimally invasive and targeted therapeutic cell delivery to the skin using microneedle devices Benedetta Gualeni, Siôn A. Coulman, D. Shah et al. · British Journal of Dermatology | 2 Sep 2017 | 66 |
| 8 | Safety, tolerability and efficacy of intradermal rabies immunization with DebioJect™ Paul Vescovo, Nils Rettby, Nirinarilala Ramaniraka et al. · Vaccine | Mar 2017 | 40 |
| 9 | Insulin Micropump with Embedded Pressure Sensors for Failure Detection and Delivery of Accurate Monitoring Dimitry Dumont-Fillon, Hassen Tahriou, Christophe Conan et al. · Micromachines | 18 Nov 2014 | 38 |
| 10 | Improved micro-flow regulator for drug delivery systems Peter Cousseau, R. Hirschi, B. Frehner et al. | 13 Nov 2002 | 32 |
| 11 | A Review of Passive Constant Flow Regulators for Microfluidic Applications E. Chappel · Applied Sciences | 10 Dec 2020 | 30 |
| 12 | The guanylhydrazone CNI-1493: an inhibitor with dual activity against malaria—inhibition of host cell pro-inflammatory cytokine release and parasitic deoxyhypusine synthase Sabine Specht, Salem Ramadan Sarite, Ilona Hauber et al. · Parasitology Research | 5 Feb 2008 | 30 |
| 13 | Implantable drug delivery devices E. Chappel · Elsevier eBooks | 16 Dec 2020 | 29 |
| 14 | 3D micromixers-downscaling large scale industrial static mixers Arnaud Bertsch, Stephan Heimgartner, Peter Cousseau et al. | 13 Nov 2002 | 29 |
| 15 | PZT films for micro-pumps K.G. Brooks, Dragan Damjanović, Andréi L. Kholkin et al. · Integrated ferroelectrics | Mar 1995 | 26 |
| 16 | Inhibition of Multidrug‐Resistant HIV‐1 by Interference with Cellular S‐adenosylmethionine Decarboxylase Activity Birgit Schäfer, Ilona Hauber, Andrea Bunk et al. · The Journal of Infectious Diseases | 22 Aug 2006 | 24 |
| 17 | Drug Delivery Micropump with Built-In Monitoring N. Schneeberger, R. Allendes, Fernando Daniel Bianchi et al. · Procedia Chemistry | Sep 2009 | 21 |
| 18 | Modeling of a Piezoelectric MEMS Micropump Dedicated to Insulin Delivery and Experimental Validation Using Integrated Pressure Sensors: Application to Partial Occlusion Management S. Fournier, E. Chappel · Journal of Sensors | 2017 | 18 |
| 19 | Micropumps for drug delivery E. Chappel, Dimitry Dumont-Fillon · Elsevier eBooks | 16 Dec 2020 | 15 |
| 20 | Passive flow control valve for protein delivery L. Cornaggia, Leonardo Conti, Mélanie T. M. Hannebelle et al. · Cogent Engineering | 2017 | 14 |
| 21 | Design and characterization of a passive flow control valve dedicated to the hydrocephalus treatment E. Chappel · Cogent Engineering | 13 Oct 2016 | 14 |
| 22 | Design and Characterization of 3-Stack MEMS-Based Passive Flow Regulators for Implantable and Ambulatory Infusion Pumps Dimitry Dumont-Fillon, Damien Lamaison, E. Chappel · Journal of Microelectromechanical Systems | 7 Jan 2020 | 13 |
| 23 | Passive flow regulators for drug delivery and hydrocephalus treatment E. Chappel, Dimitry Dumont-Fillon, S. Mefti · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE | 6 Mar 2014 | 11 |
| 24 | Formulation of composite resistive pastes for fabrication of micro-heaters N. Serra, Thomas Maeder, Pierre Lemaire et al. · Sensors and Actuators A Physical | 18 Jan 2010 | 11 |
| 25 | Dynamic Simulations of a Piezoelectric Driven MEMS Micropump S. Fournier, E. Chappel · Procedia Engineering | 2016 | 10 |
| 26 | Formulation of Composite Resistive Pastes for Micro-Heater Manufacturing N. Serra, T. Maedera, Pierre Lemaire et al. · Procedia Chemistry | Sep 2009 | 10 |
| 27 | The effect of bolus advisors on glycaemic parameters in adults with diabetes on intensive insulin therapy: A systematic review with meta‐analysis Elisabeth Johanna den Brok, Cecilie Hornborg Svensson, Maria Panagiotou et al. · Diabetes Obesity and Metabolism | 19 Mar 2024 | 9 |
| 28 | Personalized Insulin Adjustment With Reinforcement Learning: An In-Silico Validation for People With Diabetes on Intensive Insulin Treatment Maria Panagiotou, Lorenzo Brigato, Vivien Streit et al. · IEEE Access | 2025 | 8 |
| 29 | Design of a Passive Flow Regulator Using a Genetic Algorithm Dimitry Dumont-Fillon, Mélanie T. M. Hannebelle, Harald van Lintel et al. · Procedia Engineering | 2016 | 8 |
| 30 | Coding gaze tracking data with chromatic gradients for VR Exposure Therapy Bruno Herbelin, Helena Grillon, Pablo de Heras Ciechomski et al. | Nov 2007 | 6 |
| 31 | Industrialized Functional Test for Insulin Micropumps E. Chappel, R. Allendes, Fernando Daniel Bianchi et al. · Procedia Engineering | 2011 | 6 |
| 32 | Experimental characterization and modelling of microfluidic radial diffusers for passive self-regulating valves E. Chappel, Musard Hugo, Dimitry Dumont-Fillon · Global Journal of Engineering and Technology Advances | 30 Dec 2019 | 5 |
| 33 | Two-Phased Real-Time Rendering of Large Neuron Databases Pablo de Heras Ciechomski, Robin Mange, Achille Peternier | Dec 2008 | 5 |
| 34 | High precision innovative micropump for artificial pancreas E. Chappel, S. Mefti, G.-L. Lettieri et al. · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE | 6 Mar 2014 | 5 |
| 35 | Design and Characterization of an Adjustable Passive Flow Regulator and Application to External CSF Drainage E. Chappel · Micromachines | 19 Mar 2023 | 4 |
| 36 | Dry Test Methods for Micropumps E. Chappel · Applied Sciences | 30 Nov 2022 | 4 |
| 37 | Posture related in-vitro characterization of a flow regulated MEMS CSF valve Nikolaos Tachatos, E. Chappel, Dimitry Dumont-Fillon et al. · Biomedical Microdevices | 22 Feb 2020 | 4 |
| 38 | Hybrid hydrodynamic characteristic for hydrocephalus valve: A numerical investigation using electrical equivalent networks E. Chappel, Mélanie T. M. Hannebelle, L. Cornaggia et al. · Cogent Engineering | 2017 | 3 |
| 39 | On-chip thermopneumatic actuation system for coagulation time measurement Pierre Lemaire, Lynda Metref, François Bianchi et al. · Procedia Chemistry | Sep 2009 | 3 |
| 40 | seeCell: Visualization and tracking dedicated to cell analysis Robin Mange, Pablo de Heras Ciechomski, Melody A. Swartz | Dec 2008 | 2 |
| 41 | Robust alarm design strategy for medical devices: Application to air-in-line detection and occlusion management E. Chappel · Global Journal of Engineering and Technology Advances | 7 Sep 2023 | 1 |
| 42 | Preserved pulmonary vasodilative properties of aerosolized brain natriuretic peptide Hanno H. Leuchte, Jens Michalek, Oezcan Soenmez et al. · Pulmonary Pharmacology & Therapeutics | 30 Jul 2009 | 1 |
| 43 | Thermally actuated microprojector for optical display applications Sandra Schweizer, Peter Cousseau, S. Schiesser et al. · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE | 22 Aug 2000 | 1 |
| 44 | Characterising the Diffusion Functional Signature of Negative BOLD With Interleaved TMS ‐ fMRI in the Human Brain Inès de Riedmatten, Arthur P C Spencer, Roberto Martuzzi et al. · Human Brain Mapping | 15 Aug 2026 | 0 |
| 45 | Randomised Controlled Multicentre Trial to Investigate the Effectiveness of a Mobile Artificial Intelligence Solution for Diabetes Adapted Care: The MELISSA Trial Protocol Elisabeth J. den Brok, Cecilie H. Svensson, Mikkel T. Olsen et al. · Diabetes Obesity and Metabolism | 19 May 2026 | 0 |
| 46 | Digital Dilemmas: Unpacking Identity, Leisure, and Mental Health in a Screen-Saturated World B. Bediou, Anh Nguyen-Danse, J. Billieux et al. · Current Addiction Reports | 14 Mar 2026 | 0 |
| 47 | Knowledge Modelling for Automated Risk Assessment of Cybersecurity and Indirect Patient Harms in Medical Contexts Samuel M. Senior, Laura Carmichael, Stephen Taylor et al. | 2025 | 0 |
| 48 | Symposium 10 “The Newest Technical Developments in Diabetes Treatment” Jan Maria Wojcicki, Tetsuji Yamaoka, Yasuo Yoshimi et al. · Medical Entomology and Zoology | Oct 2007 | 0 |
Citations are OpenAlex's own counts, from its 2026-09-23 snapshot, so the ranking can differ from Google Scholar or Web of Science. A paper is listed for an institution when any of its authors gave it as an affiliation; retracted papers and papers whose citation count cannot be traced to citing works are left out, and a preprint and the article it became are shown once. Release dates are OpenAlex's: where a source gave only a month or a year, that is what is shown. How the lists are chosen.